Skip to catalogue content
Trade counter Free freight over US$250 Calibration certificate with every torque tool Same-day dispatch before 14:00 HKT
LIANQU TOOLWORKS
+852 4733 8597
Datasheets
Rev. 2026-11 · 18 rows
Table 1 — Full specification, True-RMS Multimeter 6000 (6000计数真有效值万用表). Values nominal at 20 °C unless stated.
MaterialFlame-retardant ABS case, silicone holster, gasket-sealed battery bay
Display6,000 counts, 3 5/8 digit, 61-segment bar graph, white backlight
DC voltage0.1 mV–1,000 V, ±(0.5% + 2)
AC voltage1 mV–750 V true RMS, 45 Hz–1 kHz, ±(1.0% + 3)
DC / AC current0.1 µA–10 A, ±(1.2% + 3), fused inputs
Resistance0.1 Ω–60 MΩ, ±(0.8% + 2)
Capacitance1 nF–60 mF, ±(2.5% + 5)
Frequency / duty5 Hz–10 MHz, ±(0.1% + 1)
ContinuityUnder 30 Ω, latched beep, 0.5 ms response
Diode test3.2 V open-circuit, 1 mA test current
Safety ratingCAT III 600 V, CAT II 1,000 V, IEC 61010-1
Fuses10 A/600 V HRC ceramic and 630 mA/250 V, field-replaceable
FunctionsData hold, MIN/MAX, relative zero, auto power off at 15 min
Battery2 × AA alkaline, about 200 h typical, low-battery indicator
Case165 × 84 × 38 mm, drop tested 1.2 m on concrete
Weight340 g with battery and holster
CertificationIEC 61010-1, CE, EMC EN 61326-1, RoHS 3
Warranty3 years, excluding fuses and battery

Measured at the LQ bench, Kowloon · tolerances per datasheet · subject to revision without notice.

  • 1 × multimeter
  • 1 × silicone holster with stand
  • 1 × pair 1,000 V test leads
  • 1 × K-type bead probe
  • 1 × 10 A HRC fuse
  • 1 × 630 mA fuse
  • 2 × AA cells
  • 1 × manual

8 line items · check against the packing slip before the carton goes out.

Table 3 — Compliance and warranty boundaries for LQ-DM-04.
Safety ratingCAT III 600 V, CAT II 1,000 V, IEC 61010-1
CertificationIEC 61010-1, CE, EMC EN 61326-1, RoHS 3
Warranty3 years, excluding fuses and battery
ConsumablesNone listed — wear parts are covered under warranty terms

Certificates are issued per unit and matched to the serial, not to the batch. Warranty boundaries by SKU.

Side by side

Compared with two other SKUs.

Full catalogue →
Table 2 — Three-SKU comparison. The highlighted column is this page.
Specification LQ-DM-04 True-RMS Multimeter 6000 LQ-TZ-06 ESD Tweezer Set 6 LQ-PD-01 Precision Driver Set 32
Price $74.00 $24.00 $42.00
Group Measurement & ESD Measurement & ESD Drivers & Pry Tools
Key rating Counts · 6,000 Pieces · 6 Hardness · 58–60 HRC
Certification IEC 61010-1, CE, EMC EN 61326-1, RoHS 3 IEC 61340-5-1, CE, RoHS 3 RoHS 3 (EU 2015/863), REACH SVHC screened
Material Flame-retardant ABS case, silicone holster, gasket-sealed battery bay 301 stainless steel, stamped and micro-hardened to HV 420 S2 shock-resisting tool steel bits, 58–60 HRC
Weight 340 g with battery and holster 12–22 g each; 104 g in the wallet 186 g complete; 41 g handle alone
Warranty 3 years, excluding fuses and battery 2 years against tip offset and spring failure 2 years on handle and bearing; bit breakage replaced free for 12 months

About this piece

True-RMS Multimeter 6000

A meter that reads what the wire is actually doing: true RMS on distorted mains, 0.1 mV resolution on a shunt, 60 MΩ on an insulation path. The 6,000-count display carries a 61-segment bar graph that updates twelve times a second, so a flickering rail shows as movement rather than a number that jumps. Inputs are fused and the case is rated CAT III 600 V, which is the rating that matters when you are inside a distribution board rather than on a bench.

Everything on this page is a measurement we can repeat: the hardness of the steel, the accuracy of the mechanism, the resistance of the coating, the number of pieces in the carton. Where a figure is a range, the range is the specification — a torque wrench that reads ±3% at 20 Nm and ±5% at 5 Nm is a different tool from one that claims ±3% flat.

Average-responding meters read a square wave about 11% high and a triac dimmer output anybody. True RMS costs a few dollars more in parts and removes a whole category of argument. Every meter we sell is true RMS, including the cheapest.

How it is made

The meter uses a 6,000-count converter with a true-RMS front end feeding a 61-segment bar graph. Inputs are protected by HRC fuses and a varistor clamp, and the case is assembled with a silicone gasket so the CAT III 600 V rating survives a wet bench rather than only a dry one.

Each unit is checked against a 0.05% reference divider on DC volts and a 0.1% AC source at 50 Hz and 1 kHz before the holster goes on. Tweezers are stamped from 301 strip, micro-hardened, matched to 0.03 mm jaw offset, then coated and pinhole-tested at 500 V.

QC reference: LQ-DM-04 / 2026-11 / batch traceable by serial.

True-RMS Multimeter 6000 in use at a repair bench
Fig. 06 LQ-DM-04 at the reference bench, Sham Shui Po — In use at the bench.

Care

Three habits that keep the numbers true.

No proprietary cleaners, no service plan. Three things you can do at the bench.

01

Verify against a reference

Check the meter against a known 10.000 kΩ resistor quarterly; check tweezers with an ESD meter annually. A reading you have not verified is an opinion.

02

Fuses are consumables

Keep a spare 10 A/600 V HRC and a 630 mA fuse on the bench. A blown fuse is not a meter fault, and a replaced fuse must be the same rating and breaking capacity.

03

Store dissipative tools dry

Coated tweezers kept in a humid drawer lose coating faster. Wipe with IPA, return to the wallet, and never autoclave or ultrasonically clean a coated tip.

Also on the counter

Three more SKUs.

All six →

Drivers & Pry Tools

Pry & Opening Kit 18

18件撬棒拆机工具组

Tips
0.4–1.6 mm
Hardness
Shore D 78
Pieces
18

$19.00$24.00